Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808

Product Details
Customization: Available
Installation
Method:
Vertical
Operation
Type:
Automatic
Still deciding? Get samples of US$ 23/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Group Corporation
Secured Trading Service
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001, IATF16949, HSE, ISO 14064, QC 080000, GMP, BSCI, BRC, SA 8000, QHSE, HACCP, BS 25999-2, ISO 13485, EICC, ANSI/ESD, SEDEX, ISO 22000, AIB, WRAP, GAP,ISO 29001, BREEAM, HQE, SHE Audits, IFS, QSR, ISO 50001, LEED, PAS 28000, FSC, ISO 17025
Import & Export Mode
Have Own Export License
  • Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
  • Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
  • Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
  • Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
  • Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
  • Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
Find Similar Products

Basic Info.

Model NO.
AS34495
Dust Collecting Method
Half Dry
Type
Filter Cartridge Dust Collector
Installation Nmethod
Vertical
Operation Ntype
Automatic
Media
Gas
Temperature
Low Temperature
Actuator
Pneumatic
Connection Form
Clamp
Material
Stainless Steel
Pressure
High Temperature
Valve Structure
Pilot Piston Structure
Power Supply
DC Solenoid Valve
Usage
Safety, Emptying, Drain, Temperature Control
Application
Industrial Usage, Household Usage
Delivery Time
Ready to Ship
OEM
Yes
Certificates
SGS BV Certificates
Transport Package
Plastic Bag and Carton
Specification
910mm*340mm*29mm
Trademark
SMCC OR NO MARK
Origin
China
HS Code
8481100090
Production Capacity
20000

Packaging & Delivery

Package Size
30.00cm * 20.00cm * 10.00cm
Package Gross Weight
2.000kg

Product Description

We are a enterprise groups engaged in researching, production, marketing and technical services. Covering 80, 000 square meters, now we have 816 employees including 167 senior professional technicians and a global network of sales and service system. The 219 sets of advanced automatic production equipment provide guarantees for high product quality. We can design and develop products to meet the exact demands of customers, and OEM customizations are also available with us. Our sound global service network can provide customers with timely after-sales technical services.
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
ASSEMBLY INSTRUCTION

NOTE!

Before the assembly of the OPTIPOW units, an accurate cleaning of the internal of the pressure tank is of great importance. Any particle in the tank could in the future give serious problems regarding the operation of the pulse valves.
The OPTIPOW valve is as standard made for vertical installation. When the valve shall operate horizontally an extra internal spring has to be used. By that the plunger will always be in closed position when pressurising the cleaning system.
The OPTIPOW is normally delivered as one unit in a special package. For detailed instructions regarding erection of separate parts, see OPTIPOW assembly drawing.
Unpack the valves at first when mounting them.
Check that there are no visible damages on the valve.
Check that there are no foreign materials inside of the valve.
Check that the top of the pulse pipe is smooth without any burrs.
Position numbers below refers those mentioned in figure 1.
Put the plunger (pos 4) on the top of the pulse pipe. Lubricate the O-ring on the outer side of the valve house (pos 1) and match the house to the plunger. When installing the pulse valve be careful not to damage the O-ring. Tum the house so that the solenoid is pointing in right direction. Screw the four bolts with fingers as long as possible and make then the last setting with tool cross-wise to avoid damages to the O-ring. Torque according to specifications.

NOTE!
The valve house is sensitive to strikes on the bottom part of the house(see sketch below).
If the house is sutyected to a strike and the plunger is not able to move up and down inside the house, you may use a hammer or a conical tool to restore the shape of the taps of the housing, thus letting the plunger move freely up and down.
                                              
Notes regarding spare part installation
When receiving an OPTIPOW unit as spare part there are some additional points to consider at the installation.
Before dismounting the faulty OPTIPOW from the pressure tank, check the following.
  • Unpack the valves at first when mounting them.
  • Check that there are no visible damages on the valve.
  • Check that there are no foreign materials inside of the valve.
  • Check solenoid label, correct type mounted.
  • ATTENTION!  Make sure the pressure tank has been depressurised down to
          surrounding pressure.
NOTE!
Due to risk of particles, moist and other foreign objects, could enter the tank never leave the pressure tank unattended with an open tank hole. If job cannot be completed, remount the old OPTIPOW unit or in other way cover the hole. Never pressurizes an uncompleted tank.
Dismount the intended OPTIPOW unit.
Inject, through the hole, the condition of the internal of the pressure tank, particles, moist etc.
If necessary, clean the internal of the tank with a vacuum cleaner until satisfied result has been archived.
When mounting the spare part OPTIPOW, follow the assembly instruction given in section 5.1.

PILOT AIR CONNECTION 

The pilot air for the solenoid is taken from the incoming tube to the pressure tank. The pipefpr the pilot air is common for all valves in one tank and is connected upstream the main on- off valve of respective tank.
The pipe should have an on-off valve and a non-return valve which ensures that pressure is kept also if pressure decreases during pulsing.

NOTE: 
If a separate feeding pipe for the pilot air is used the pressure for the pilot air should be approx equal to pressure in tank.

A too high pressure will give a remaining deformation to the membrane, which will reduce the lifetime and have a reducing effect on the function of the pulse cleaning.
 

TESTING OF INSTALLATION 

General
When all pulse valves are mounted, the tank unit should be tested regarding leakage as well as function of the individual pulse valves. Principles for the testing and acceptable results should be according to description below.

Testing procedure for tank unit
1.Properly secure the complete assembly to the floor or a non-movable test fixture and then pressurize the tank unit to 200 kPa (2 bar) . Note that the pilot air should have the same pressure. Eliminate eventual leakage in the connections.
If it is impossible to achieve a pressure in the tank check the following points:
If there is a leakage through evacuation ports "B".
Check that the pilot air is connected and that there are no leakages in the connections.
Replace solenoid valve. Note the position of the mark on the side of the solenoid vs. The slit in the top cover when installing.
If a particular valve is leaking; dismount that and check that the plunge is operating free.
If necessary clean the surfaces.
If it is a common leakage; dismount all valves and check measure "A" , picture 8. If necessary, machine the surface of the pulse pipe. Note that the top of the pulse pipes must after machining be polished to avoid sharp edges and finally the tank has to be cleaned.
2.Turn off air supply.
3.Check pressure decrease in tank as a function of time. Allowed pressure decrease is 50 kPa per minute. Even if there is a higher leakage continue to 4.
4.Check the function of each valve by pulsing from 200 kPa. Repeat this for 3 cycles.
5.Repeat from 3. If the leakage still is high try to find out if there is some valve leaking more than other, dismount that and check plunge sealing surface and secondly measure "A" . If necessary, maching surface to right tolerance.
6.Mount valve and start from 3 again. This is to be repeated until an acceptable result is achieved.
7.The final result of the testing should be documented for each tank unit according to example on appendix A. A copy of the result should be returned back to the orderer but also enclosed with the pressure tank at delivery.
 
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
Similar Products
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
 
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808

Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
Company Certificates
Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808
WHY CHOOSE US 

1. Reliable Quality Assurance System;
2. Cutting-Edge Computer-Controlled CNC Machines;
3. Bespoke Solutions from Highly Experienced Specialists;
4. Customization and OEM Available for Specific Application;
5. Extensive Inventory of Spare Parts and Accessories;
6. Well-Developed Worldwide Marketing Network;
7. Efficient After-Sale Service System

Founded in 1997, Located in Qingdao, China. Qingdao Star Machine Technology Co., Ltd. Is a high-tech enterprise specialized in researching & development, manufacturing and sales of industrial roller chains and sprockets and other conveyor accessories, alstom optipow plunger pulse diaphragm solenoid valve and accessories.

We have a global sales network and service system. At present, there are more than 150 distributors and business cooperative partners in more than 30 countries, including Vietnam, Korea, Thailand, Bangladesh, Singapore, Philippines, Malaysia, Russia, Kazakhstan, Uzbekistan, Ukraine, Iran, Saudi Arabia, Chile, Brazil, Canada, the United States, Mexico, Poland and other countries. "Honesty, efficiency, coordination, innovation" is our corporate culture. "First class quality, reasonable price and timely service" is is our company's unremitting pursuit.


Pulse Piton Alstom Optipow Valve Membrane Diaphragm for V2549808

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier