Product name |
Article number |
Pos. no. |
OPTIPOW 105(24VDC) |
V1617803-0100 |
1 |
OPTIPOW 105 (110V 60Hz, 100V 50/60Hz) |
V1617803-0200 |
1 |
OPTIPOW 105 (110V 50Hz) |
V1617803-0300 |
1 |
OPTIPOW 105 (120V 60Hz) |
V1617803-0400 |
1 |
OPTIPOW 105 (220V 50Hz) |
V1617803-0500 |
1 |
OPTIPOW 105 (UR-CERTIFIED 120V 60Hz ) |
V1617803-0600 |
1 |
OPTIPOW 105 (without solenoid, revolving 90° C) |
V1617803-0800 |
~ |
Coupling Set |
V3592382-0000 |
~ |
Membrane |
V4549902-0100 |
2 |
O-Ring (Fluor rubber 64.5 x 3.1) |
8003-5573 |
3 |
O-Ring (Nitril 70SH 64.5 x 3.1) |
2136-1422 |
3 |
O-Ring (114.5 x 3.1) |
2136-1435 |
4 |
Pilot Cover |
V3630501-0100 |
5 |
Plate |
V3630524-0100 |
6 |
Plunger |
V3630527-0100 |
7 |
Round Washer (SS3576-10-200HV FE/ZN45) |
4903-2173 |
~ |
Rubber Disc |
V3630530-0100 |
8 |
Rubber Disc |
V3640661-0100 |
8 |
Solenoid Valve(24 V DC) |
V3611471-0100 |
9 |
Solenoid Valve (100 V, 60 Hz) |
V3611471-0201 |
9 |
Solenoid Valve (110 V, 50 Hz) |
V3611471-0300 |
9 |
Solenoid Valve (110 V, 60 Hz) |
V3611471-0200 |
9 |
Solenoid Valve (120 V, 60 Hz) |
V3611471-0400 |
9 |
Solenoid Valve (120V, 60 Hz-UL CERTIFIED) |
V3640645-0200 |
9 |
Solenoid Valve (230V, 50 Hz) |
V3611471-0500 |
9 |
ALSTOM OPTIPOW AIR DUST COLLECTOR INTRODUCTION
The compact pulse valve for the Optipulse fabric filters of different types.
is a result of many years of experiences within the fabric filter technology area.
is quick acting with high efficiency.
has small dimensions, the figure after the name stands fir the diameter of the plunger.
is primarily designed to be used in combination with circular pressure tank.
is easy to install and make service to.
has a very robust design, designed for normal use at air pressure up to 600kPa (6bar).
Normal max operating temperature (compact pulse valve) 50°C.
ALSTOM OPTIPOW AIR DUST COLLECTOR MAIN PARTS
ALSTOM OPTIPOW AIR DUST COLLECTOR DIMENSION SKETCH AND ASSEMBLY
For increasing the locking of all bolts, use LOCKTITE 577 or similar.
PILOT AIR CONNECTION
The pilot air for the solenoid is taken from the incoming tube to the pressure tank. The pipefpr the pilot air is common for all valves in one tank and is connected upstream the main on- off valve of respective tank.
The pipe should have an on-off valve and a non-return valve which ensures that pressure is kept also if pressure decreases during pulsing.
NOTE:
If a separate feeding pipe for the pilot air is used the pressure for the pilot air should be approx equal to pressure in tank.
A too high pressure will give a remaining deformation to the membrane, which will reduce the lifetime and have a reducing effect on the function of the pulse cleaning.
ALSTOM OPTIPOW AIR DUST COLLECTOR TESTING OF INSTALLATION
General
When all pulse valves are mounted, the tank unit should be tested regarding leakage as well as function of the individual pulse valves. Principles for the testing and acceptable results should be according to description below.
Testing procedure for tank unit
1.Properly secure the complete assembly to the floor or a non-movable test fixture and then pressurize the tank unit to 200 kPa (2 bar) . Note that the pilot air should have the same pressure. Eliminate eventual leakage in the connections.
If it is impossible to achieve a pressure in the tank check the following points:
If there is a leakage through evacuation ports "B".
Check that the pilot air is connected and that there are no leakages in the connections.
Replace solenoid valve. Note the position of the mark on the side of the solenoid vs. The slit in the top cover when installing.
If a particular valve is leaking; dismount that and check that the plunge is operating free.
If necessary clean the surfaces.
If it is a common leakage; dismount all valves and check measure "A" , picture 8. If necessary, machine the surface of the pulse pipe. Note that the top of the pulse pipes must after machining be polished to avoid sharp edges and finally the tank has to be cleaned.
2.Turn off air supply.
3.Check pressure decrease in tank as a function of time. Allowed pressure decrease is 50 kPa per minute. Even if there is a higher leakage continue to 4.
4.Check the function of each valve by pulsing from 200 kPa. Repeat this for 3 cycles.
5.Repeat from 3. If the leakage still is high try to find out if there is some valve leaking more than other, dismount that and check plunge sealing surface and secondly measure "A" . If necessary, maching surface to right tolerance.
6.Mount valve and start from 3 again. This is to be repeated until an acceptable result is achieved.
7.The final result of the testing should be documented for each tank unit according to example on appendix A. A copy of the result should be returned back to the orderer but also enclosed with the pressure tank at delivery.
Fabric filter (FF)
The fabric filter (or baghouses or bag filters) uses a filter medium to separate particulate matter (PM) from the flue gases. The PM is deposited on the surface of the fabric filter, which can be made of different materials depending on the physical and chemical composition of the flue gas. The dust is removed periodically when the bags are cleaned.
Qingdao Star Machine Technology Co.,ltd. fabric filters have been developed over the past decade to reduce particulate emissions, capital cost and footprint. These filters offer a robust solution for power generation and industrial applications, especially when the dust characteristics are challenging or variable. Qingdao Star Machine Technology Co.,ltd. offers both high-ratio (pulse jet) and low-ratio (reverse air) FF designs. Qingdao Star Machine Technology Co.,ltd. fabric filter may be used as a stand-alone unit or integrated into hybrid filters (ESP and FF) or multi-pollutant control equipment (TurboSorp, Turbo-CDS, NID or SDA). In addition, Qingdao Star Machine Technology Co.,ltd. is actively collaborating with filter bag manufacturers to offer guarantees for the lowest emissions and longest bag lifetime on the market for selected processes.
ALSTOM OPTIPOW AIR DUST COLLECTOR SPECIFICATION AND SPARE PARTS LIST
SEE ALSO
A Professional Alstom optipow 135 solenoid valve manufacturer, the service life can reach 1,000,000 times. Low temperature resistance -60 ° C and high temperature 150 ° C. Widely used in thermal power plant air purification and dust removal, glass factory dust removal, laboratory dust removal, and other industrial dust removal. We have a sales system and after-sales service system all over the world. Our goal is to continuously improve quality and continuously reduce costs, till customer satisfaction.
Low loss of compressed air: the OPTIPOW pulse valve reduces the amount of compressed air consumption compared to diaphragm type.
Compact size: OPTIPOW pulse is much smaller than the diaphragm valve shape the pulse valve shape, which means that the bag spacing not is restricted by the size of valve, only the process parameters (gas Bubbe, without filter, fly ash type and concentration) determines the bag size, two OPTIPOW pulse valve * * * short distance you can go to 160mm.
OPTIPOW pulse valve has two specifications: 105 and 135, the number represents the diameter of the piston.
ALSTOM piston type pulse valve OPTIPOW
Piston diameter 105135mm
The number of filter bags: 30
Length of filter bag: 10M
Piston type pulse valve V1585320
Piston type pulse valve V3630501
OPTIPOW 105 (24 VDC ) V1617803-0100 [1]
OPTIPOW 105 (110V 60 Hz, 100V 50/60Hz) V1617803-0200 [1]
OPTIPOW 105 (110V, 50 Hz) V1617803-0300 [1]
OPTIPOW 105 (110V 50Hz, 120V 60Hz) V1617803-0400 [1]
OPTIPOW 105 (220V, 50 Hz) V1617803-0500 [1]
OPTIPOW 105 (UR-CERTIFIED 120V,60HZ) V1617803-0600 [1]
OPTIPOW 105 (without solenoid, revolving 90° C) V1617803-0800 -
Coupling set V3592382-0000 -
Membrane V4549902-0100 (2)
O-Ring (Fluor rubber 64,5 x 3) 8003-5573 (3)
O-Ring (Nitril 70SH 64,5 x 3) 2136-1422 (3)
O-Ring (114,5 x 3) 2136-1435 (4)
Pilot cover V3630501-0100 (5)
Plate V3630524-0100 (6)
Plunger V3630527-0100 (7)
Round washer (SS3576-10-200HV FE/ZN45 Erection details) 4903-2173 -
Rubber disc V3630530-0100 (8)
Rubber disc V3640661-0100 (8)
Screw (ISO4762-M10x30-8.8 ZN8C, Erection details) 2034-2495 -
Solenoid valve (24 V DC) V3611471-0100 (9)
Solenoid valve (100 V, 60 Hz) V3611471-0201 (9)
Solenoid valve (110 V, 50 Hz) V3611471-0300 (9)
Solenoid valve (110 V, 60 Hz) V3611471-0200 (9)
Solenoid valve (120 V, 60 Hz) V3611471-0400 (9)
Solenoid valve (120 V, 60 Hz - UL certified) V3640645-0200 (9)
Solenoid valve (230 V, 50 Hz) V3611471-0500 (9)
WHY CHOOSE US
1. Reliable Quality Assurance System;
2. Cutting-Edge Computer-Controlled CNC Machines;
3. Bespoke Solutions from Highly Experienced Specialists;
4. Customization and OEM Available for Specific Application;
5. Extensive Inventory of Spare Parts and Accessories;
6. Well-Developed Worldwide Marketing Network;
7. Efficient After-Sale Service System
Founded in 1997, Located in Qingdao, China. Qingdao Star Machine Technology Co., Ltd. Is a high-tech enterprise specialized in researching & development, manufacturing and sales of industrial roller chains and sprockets and other conveyor accessories, alstom optipow plunger pulse diaphragm solenoid valve and accessories.
We have a global sales network and service system. At present, there are more than 150 distributors and business cooperative partners in more than 30 countries, including Vietnam, Korea, Thailand, Bangladesh, Singapore, Philippines, Malaysia, Russia, Kazakhstan, Uzbekistan, Ukraine, Iran, Saudi Arabia, Chile, Brazil, Canada, the United States, Mexico, Poland and other countries. "Honesty, efficiency, coordination, innovation" is our corporate culture. "First class quality, reasonable price and timely service" is is our company's unremitting pursuit.
We are a enterprise groups engaged in researching, production, marketing and technical services. Covering 80, 000 square meters, now we have 816 employees including 167 senior professional technicians and a global network of sales and service system. The 219 sets of advanced automatic production equipment provide guarantees for high product quality. We can design and develop products to meet the exact demands of customers, and OEM customizations are also available with us. Our sound global service network can provide customers with timely after-sales technical services.
OPTIPOW AIR DUST COLLECTOR EXPRESS DELIVERY AVAILABLE